Backflow prevention devices in White Plains, NY get installed and tested by licensed plumbers.
Westchester County’s own Cross Connection Control Program is based in White Plains, NY, and it requires owners of commercial properties and irrigation systems, or any connection through which contaminated water could flow back into the public supply, to have a certified backflow test every year. Action Construction installs and repairs the assemblies, runs the annual certified test, and files the results with the water authority to keep the property compliant.
Backflow means water running the wrong way through a plumbing connection, and a backflow preventer is the mechanical device built to stop it. If pressure falls in the public main, because a hydrant is in use, a main has broken, or a fire is drawing heavy volume, the pull can reverse the flow through any cross connection. The back siphoned water brings along what it passed through, whether that is lawn chemicals, boiler treatment, or process water, and it ends up in the drinking supply.
The county program is Westchester’s Cross Connection Control Program, and the Consumer Protection office that administers it is in White Plains. It calls for assemblies on commercial buildings, lawn irrigation, boiler make up lines, fire suppression systems, and any other cross connection. A property with a sprinkler service, a commercial kitchen, a boiler, or an irrigation system nearly always carries at least one assembly the county expects to see tested every year, and often more than one. Our crews work to those same county requirements day in and day out.
The wave of transit oriented high rise and condo construction near the Metro North station has brought a real increase in backflow device requirements, because every new domestic and fire line connection into a multi story building needs its own assembly. A property manager bringing a new City Center building online should expect several assemblies across the domestic supply, the fire suppression system, and any boiler feed, each requiring its own annual test and report.
Our first visit to a property starts with a survey for cross connections that are still unprotected: a hose bibb with no vacuum breaker, an irrigation tie in, a boiler feed. An unprotected connection found later is a violation on its own, just as a failed test is. After the survey comes the test itself, repeated once a year on every assembly. Our tester attaches a calibrated differential pressure gauge, closes the shutoffs, opens the test cocks in sequence, and records how each check holds pressure and when the relief valve opens, which takes 20 to 30 minutes per device for most assemblies. Only a plumber who holds the state backflow tester certification may do this work, and the results go to the water authority. Reports are submitted by our office, so nothing lapses.
A testing notice that carries a deadline sets the clock, so count from the date on it. Untested assemblies can draw a violation, and if the lapse continues the water authority may cut service until the test is filed. Doing several devices on one visit lowers the cost for each.
Worn internal checks or a sticky relief valve are the usual reasons an assembly fails, and a rebuild kit normally brings it back, with replacement reserved for older brass bodies that cannot be saved. Our stock of kits for the common makes means a repair and retest can often be done on the same visit, so the property is not left out of compliance while a part is on order.
Each new installation is
A device behind pressure or water quality complaints is diagnosed along with the plumbing it feeds, because we handle that plumbing too.
An irrigation backflow assembly sits outdoors and has to survive freezing weather, so the work falls at both ends of the season. Spring brings the startup and a test once the system is recharged. Fall brings winterization, when the lines are blown out and the assembly is drained or removed so a Westchester winter cannot crack it. Finding a cracked assembly in April means a replacement and a delayed startup, which is why the fall visit pays for itself.
A failed assembly on a domestic line can look like a hidden leak at first because it causes pressure or water quality trouble, and backflow itself is one line item among our wider commercial plumbing services.
Every service we provide in the city appears on our White Plains plumbing services hub.
Two types account for most of our assembly work: the double check valve assembly, which guards lower hazard connections like lawn irrigation and some fire lines, and the reduced pressure zone assembly, which goes where the hazard is greater, as with a boiler on chemical treatment or a commercial process line. Because a reduced pressure assembly is built with a relief port that releases water when its internal checks foul, a puddle beneath one after a pressure event usually means the device did its job and is due for service, not that it is broken. Irrigation assemblies installed outdoors typically give out because of freezing and grit that reaches the first check.
Inside mechanical rooms, including the riser rooms of downtown office towers and high rise condos, failure traces to
The report notes the make, model, and serial each time, which gives the next annual test its starting point.
Expect a modest flat fee per assembly, less per device if several are tested at once. The test is yearly and certified: with a calibrated gauge, the tester confirms the assembly still blocks reverse flow, which takes roughly 20 to 30 minutes a device. If one fails, repair or replacement is quoted on its own.
More goes into it than the time at the device. The tester’s certification, a calibrated gauge that has to go out for recertification, and the report filed with the water authority all carry a cost. When several devices are tested in one visit, that fixed cost is divided among them and each costs less.
Only one with the state backflow tester certification, and that includes us. Testing, installation, and repair of the assemblies all come from the same company, which means a failure is corrected and retested without a second contractor and without a lapse in compliance while waiting on parts.
No. A certified tester has to perform the yearly test, using calibrated equipment, and the results go to the water utility, and also to Westchester County’s own Cross Connection Control Program for commercial properties. Self certifying is not an option for a property owner.
Frequently more than one. Domestic water, fire suppression, and in some buildings the boiler feed each get their own assembly, and every assembly is tested once a year and reported on separately. We can plan a single visit that tests every assembly in the building.
Licensed & Insured | Residential & Commercial | Serving CT & NY
We use cookies to improve your experience on our site. By using our site, you consent to cookies.
Manage your cookie preferences below:
Essential cookies enable basic functions and are necessary for the proper function of the website.
These cookies are needed for adding comments on this website.
You can find more information in our Cookie Policy and Privacy Policy.